Product Description: rack mounted ATS, 16a, 230V, (2) IEC 309 import, (1) IEC 309 export
output
Rated output voltage
230V
Cable length
0.91M
Maximum total current consumption
sixteen
Output connection
(1) IEC 309 16A (2P + e) (battery backup)
input
Rated input voltage
200V , 208V , 230V
Input frequency
50/60 Hz
Input terminal type
IEC 309 16A 2P+E
Input line length
0.91M
Acceptable input voltage
200-240 VAC
Number of power lines
two
carrying capacity
3840 VA
Maximum input current
16 A
Maximum line current
16 A
Physical parameters
high
44 , 4.4 cm
wide
432 , 43.2 cm
deep
236 , 23.6 cm
Rack height
1 U
Net weight
4.21 kg
Gross weight
5.95 kg
Shipping height
114 , 11.4 cm
Shipping width
600 , 60.0 cm
Depth of shipment
349 , 34.9 cm
colour
Black
Environmental Science
working temperature
-5 - 45 °C
Working relative humidity
0 - 95 %
Operating height
0-3000 M
Storage temperature
-25 - 65 °C
Storage relative humidity
0 - 95 %
Storage height
0-15000 M
Conformity
Management certification
C-tick, CE, en 55022 a, en 55024, gost, TUV, VCCI a
Standard warranty
Repair or replace within 2 years
Provide sustainable status
RoHS
accord with
REACH
Reach: without SVHC
PEP
Available in the documentation tab
EOLI
Available in the documentation tab
Battery directive
accord with
Battery precautions
ts_ Battery_ Notes
Ap7722a features
Rack mounted ATS, 16a, 230V, (2) IEC 309 inlet, (1) IEC 309 outlet
Features and advantages of rack automatic transfer switch
usability
Remote management capability
The network management interface with rich functions provides users with the ability to manage ATS based on Web and SNMP
And the standard remote management function of Telnet management interface. Users can use the Internet at the remote end
Network to access, configure and manage ATS. (Note: only network products have this function)
Dual input power supply
Provide redundant AC power for connected loads. Two AC lines supply power to the unit, and if
If the main AC power supply fails, the unit will automatically switch to the standby power supply
Wide range of input and output connections
The product family includes various input and output connections to distribute 120V, 208v or 230V power
To multiple outlets. Having a variety of inputs and outputs allows users to adapt to changing power requirements
. APC provides a unit up to 5.7kw with a single branch unit.
Wide range of input and output connections
The product family includes various input and output connections to distribute 120V, 208v or 230V power to the
Multiple outlets. Having a variety of inputs and outputs allows users to adapt to changing power requirements.
APC provides a unit up to 5.7kw with a single branch unit.
Rack mountable
It only occupies 1 U of valuable rack space. Place power where you need it most - in a rack close to the device.
information display
Indicates the status of two AC input power sources, which power source is selected as the main power source, and which power source is selected
The power supply is supplying power to the load. At the same time, it also provides graphical power supply from input to output
Load flow diagram, so that users can clearly and easily understand the flow direction of power supply and AC
Enter the status of the power supply. (Note: non network products only provide input power status indication,
Without power flow diagram)
Dual input power supply
Provide redundant AC power for connected loads. Two AC lines supply power to the unit, and if the main
In case of AC power failure, the unit will automatically switch to the standby power supply
information display
Indicates the status of two AC input power sources, which power source is selected as the main power source, and which power source is selected
The power supply is supplying power to the load. At the same time, it also provides graphical power supply from input to output
Load flow diagram, so that users can clearly and easily understand the flow direction of power supply and AC
Enter the status of the power supply. (Note: non network products only provide input power status indication,
Without power flow diagram)
Rack mountable
It only occupies 1 U of valuable rack space. Place power where you need it most - near the device
In the rack.
Dual input power supply
Provide redundant AC power for connected loads. Two AC lines supply power to the unit, and if the main
In case of AC power failure, the unit will automatically switch to the standby power supply
Dual input power supply
Provide redundant AC power for connected loads. Two AC lines supply power to the unit, and if
If the main AC power supply fails, the unit will automatically switch to the standby power supply
Remote management capability
The network management interface with rich functions provides users with the ability to manage ATS based on Web and SNMP
And the standard remote management function of Telnet management interface. Users can use the Internet at the remote end
Network to access, configure and manage ATS. (Note: only network products have this function)
Fast switching
Automatic transfer switch (ATS) has fast transfer speed, and the transfer time meets the industry standard
To ensure the reliable operation of the load in the switching process. For the load equipment, ATS starts from one circuit
The switching from the source to another power supply is seamless, which will not cause the interruption of load operation.
Contact: Qian miao
Phone: 137 6432 5676
Tel: 021-5911 8259
Email: schneider-ups@foxmail.com
Add: 8218 JINDA Road, Fengxian District, Shanghai